Enhanced Safety Circuit Breaker Equipment for Reliable Switchgear

Product Details
Customization: Available
Certification: ISO9001
Shell Material: Steel Plate
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Low MOQ
The MOQ for the supplier's products is 1
Customization from Designs
The supplier provides design based customization services
ODM Services
The supplier provides ODM services
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (18)
  • Enhanced Safety Circuit Breaker Equipment for Reliable Switchgear
  • Enhanced Safety Circuit Breaker Equipment for Reliable Switchgear
  • Enhanced Safety Circuit Breaker Equipment for Reliable Switchgear
  • Enhanced Safety Circuit Breaker Equipment for Reliable Switchgear
  • Enhanced Safety Circuit Breaker Equipment for Reliable Switchgear
  • Enhanced Safety Circuit Breaker Equipment for Reliable Switchgear
Find Similar Products
  • Overview
  • Product Description
  • Use Environment
  • Customizable products
  • About Us
  • Ordering Instructions
Overview

Basic Info.

Model NO.
NCGKYN01
Voltage Level
High Voltage
Installation
Fixed
Structure
Cabinet
Current
AC
Output Frequency
50Hz
Operating Voltage
380V
Operating Current
5000A
Use Environment
-15ºC-50ºC
Warranty
24 Months
Transport Package
Standard Export Wooden Box with Pallet
Specification
2625mm*1400mm*2855mm
Trademark
Newcom
Origin
Fujian, China
HS Code
8504409999
Production Capacity
2000pieces/Month

Product Description

Product Description

Enhanced Safety Circuit Breaker Equipment for Reliable Switchgear
Use Environment

1. To ensure the superior performance of the Reliable Distribution Switchgear with Enhanced Insulation for Safety, it is paramount that the ambient air temperature is maintained between the optimal range of no more than +40°C and no less than -5°C. Equally important, the average temperature over any given 24-hour period must remain under +35°C to guarantee continuous functionality and efficiency.

2. This product is meticulously engineered for flawless indoor installation, ensuring peak performance in environments where the altitude does not exceed 2000 meters above sea level. This specification is key to upholding the product's robust functionality and unwavering reliability.

3. The relative humidity of the ambient air should optimally be kept at or below 50% when the temperature peaks at +40°C. At lower temperatures, a higher relative humidity is acceptable, such as allowing up to 90% at +20°C, while carefully managing and monitoring potential condensation due to temperature variations.

4. During installation, it is essential to pay keen attention to the equipment's inclination; it must not deviate beyond 5% from the vertical plane to preserve the device's operational integrity and efficiency.

5. The installation site should be a haven free from significant vibrations and impacts, ensuring a stable environment that protects the electrical components from potential corrosion and other environmental threats.

6. For users with unique requirements, we encourage direct discussions with the manufacturer to explore customized solutions that meet your specific operational demands and preferences.

Customizable products
Enhanced Safety Circuit Breaker Equipment for Reliable Switchgear

About Us

Enhanced Safety Circuit Breaker Equipment for Reliable Switchgear
Ordering Instructions

When placing an order, the User shall provide:

1. A comprehensive and detailed diagram of the main circuit distribution system's phase layout, including specifications such as rated working voltage, rated working current, protection device current settings, and any additional technical parameters to ensure bespoke manufacturing and an optimal setup tailored to your needs.

2. Clearly define the specifications for both incoming and outgoing cables to assure precision in connectivity, thereby maximizing efficiency and performance.

3. Furnish the model, specification, and quantity details of all key electrical components within the differential cabinet to enable precise customization in alignment with your operational requirements.

4. Should bus extrusion or ductwork be required between switch cabinets or incoming cabinets, please provide exact data such as span and height from the ground to ensure perfect alignment and seamless installation.

5. If the switch cabinet is intended for use in special environmental conditions, these conditions must be thoroughly detailed during the ordering process to ensure that the product is both suitable and resilient to meet those specific challenges.

6. Specify the preferred surface color of the switch cabinet alongside any unique requirements to ensure the final product aligns with your aesthetic vision and functional expectations.