Product Description
GZDW series DC screen with cadmium nickel battery, floating charger, equipped with automatic detection and alarm device, with long service life, pollution-free, easy maintenance, stable voltage, ultra-low internal resistance output to withstand large current impact and strong adaptability and high reliability characteristics, is a more ideal DC operation power supply device, can be widely used in 500kV and below the substation and below the power plant, can also be used in metallurgy, mines, petroleum, radio and television, computer room, underground railway, high-rise building and other departments, as DC control, Signal power supply, power-off protection and circuit breaker operating mechanism opening and closing power supply.
This product complies with the JB/T5777.4-2000 standard of "General Technical Conditions and Safety Requirements for DC Power Supply Equipment in Power Systems".
Use Environment
1.The ambient air temperature is not higher than +40°C and not lower than -5°C. The average temperature within 24 hours must not be higher than +35°C.
2.For indoor installation and use, the altitude of the place of use shall not exceed 2000m.
3.The relative humidity of the surrounding air does not exceed 50% at the maximum temperature of +40°C, and a large relative humidity is allowed at lower temperatures. (e.g. 90% at +20°C) is concerned about the effects of occasional condensation due to temperature changes.
4.The inclination between the equipment and the vertical plane when installed is not more than 5%.
5.The equipment should be installed in a place where there is no violent vibration and impact, and a place where the electrical components are not enough to be corroded.
6.When the user has special requirements, negotiate w2ith the manufacturer to solve the problem.
Customizable products
About Us
Ordering Instructions
When placing an order, the User shall provide:
1. Main circuit distribution system diagram phase layout diagram. Rated working voltage, rated working current, protection device walking current and necessary technical parameters.
2. Indicate the specifications of incoming and outgoing cables.
3. The model, specification and quantity of the main electrical components in the differential cabinet.
4. If the bus extrusion or bus duct is required between the switch cabinets or the incoming cabinets, the specific required data such as span and height from the ground shall be indicated.
5. When the switch cabinet is used under special environmental conditions, it should be detailed when ordering.
6. Surface color of the switch cabinet and other specific requirements.