Enhanced Safety Switchgear for Low Voltage Distribution Protection Devices

Product Details
Customization: Available
Certification: ISO9001
Shell Material: Steel Plate
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Low MOQ
The MOQ for the supplier's products is 1
Customization from Designs
The supplier provides design based customization services
ODM Services
The supplier provides ODM services
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (19)
  • Enhanced Safety Switchgear for Low Voltage Distribution Protection Devices
  • Enhanced Safety Switchgear for Low Voltage Distribution Protection Devices
  • Enhanced Safety Switchgear for Low Voltage Distribution Protection Devices
  • Enhanced Safety Switchgear for Low Voltage Distribution Protection Devices
  • Enhanced Safety Switchgear for Low Voltage Distribution Protection Devices
  • Enhanced Safety Switchgear for Low Voltage Distribution Protection Devices
Find Similar Products
  • Overview
  • Product Description
  • Use Environment
  • Customizable products
  • About Us
  • Ordering Instructions
Overview

Basic Info.

Model NO.
NCGKYN01
Voltage Level
High Voltage
Installation
Fixed
Structure
Cabinet
Current
AC
Output Frequency
50Hz
Operating Voltage
380V
Operating Current
5000A
Use Environment
-15ºC-50ºC
Warranty
24 Months
Transport Package
Standard Export Wooden Box with Pallet
Specification
2625mm*1400mm*2855mm
Trademark
Newcom
Origin
Fujian, China
HS Code
8504409999
Production Capacity
2000pieces/Month

Product Description

Product Description

Enhanced Safety Switchgear for Low Voltage Distribution Protection Devices
Use Environment

1. To guarantee the peak performance of the Reliable Distribution Switchgear adorned with Enhanced Insulation for utmost safety, it is essential that the ambient air temperature remains within a comfortable range from no more than +40°C to no less than -5°C. Moreover, ensuring that the daily average temperature does not exceed +35°C is vital in maintaining its exceptional functionality.

2. Crafted for impeccable indoor installation, this innovative product thrives in settings where the altitude remains gracefully below 2000 meters above sea level, ensuring steadfast functionality and unwavering reliability.

3. For optimal performance, it is advisable that the surrounding air's relative humidity stays at a maximum of 50% when the temperature peaks at +40°C. However, at cooler temperatures, a higher humidity level is allowable, such as reaching up to 90% at +20°C. It's crucial to consider the possibility of condensation due to temperature shifts.

4. During installation, careful attention must be given to the inclination of the equipment, ensuring it does not exceed a 5% deviation from the vertical plane. This is pivotal to preserving its operational integrity.

5. The installation site must remain devoid of intense vibrations and impacts, creating a stable haven where electrical components remain safeguarded against potential corrosion, ensuring longevity and reliability.

6. Users with unique requirements are warmly invited to engage in discussions with the manufacturer. Together, they can discover tailored solutions that perfectly align with their specific needs and desires.

Customizable products
Enhanced Safety Switchgear for Low Voltage Distribution Protection Devices

About Us

Enhanced Safety Switchgear for Low Voltage Distribution Protection Devices
Ordering Instructions

When placing an order, the User shall provide:

1. A comprehensive and detailed diagram of the main circuit distribution system phase layout is required. Include the rated working voltage, rated working current, protection device current settings, and any other essential technical parameters. This ensures precise manufacturing and flawless setup tailored to your specifications.

2. It is imperative to clearly specify the specifications for both incoming and outgoing cables, guaranteeing absolute precision in connectivity and overall efficiency.

3. Provide detailed specifications, models, and quantities of all primary electrical components within the differential cabinet. This allows for exact customization to seamlessly fit your operational requirements.

4. Should bus extrusion or ductwork be necessary between switch cabinets or incoming cabinets, please provide exact measurements such as span and height from the ground. This ensures perfect alignment and effortless installation.

5. For usage in special environmental conditions, it is crucial to elaborate on these during the ordering process. This ensures the product's suitability and resilience, tailored to withstand those specific conditions.

6. Indicate your preferred surface color of the switch cabinet along with any additional specific requirements. This ensures the final product not only meets your aesthetic preferences but also aligns with your functional expectations.