Advanced High Quality Switchgear for Optimal Electrical Distribution Safety

Product Details
Customization: Available
Certification: ISO9001
Shell Material: Steel Plate
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Low MOQ
The MOQ for the supplier's products is 1
Customization from Designs
The supplier provides design based customization services
ODM Services
The supplier provides ODM services
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (18)
  • Advanced High Quality Switchgear for Optimal Electrical Distribution Safety
  • Advanced High Quality Switchgear for Optimal Electrical Distribution Safety
  • Advanced High Quality Switchgear for Optimal Electrical Distribution Safety
  • Advanced High Quality Switchgear for Optimal Electrical Distribution Safety
  • Advanced High Quality Switchgear for Optimal Electrical Distribution Safety
  • Advanced High Quality Switchgear for Optimal Electrical Distribution Safety
Find Similar Products
  • Overview
  • Product Description
  • Use Environment
  • Customizable products
  • About Us
  • Ordering Instructions
Overview

Basic Info.

Model NO.
NCGKYN01
Voltage Level
High Voltage
Installation
Fixed
Structure
Cabinet
Current
AC
Output Frequency
50Hz
Operating Voltage
380V
Operating Current
5000A
Use Environment
-15ºC-50ºC
Warranty
24 Months
Transport Package
Standard Export Wooden Box with Pallet
Specification
2625mm*1400mm*2855mm
Trademark
Newcom
Origin
Fujian, China
HS Code
8504409999
Production Capacity
2000pieces/Month

Product Description

Product Description

Advanced High Quality Switchgear for Optimal Electrical Distribution Safety
Use Environment

1. Experience the pinnacle of performance with our Reliable Distribution Switchgear, meticulously engineered with Enhanced Insulation for superior Safety. To achieve its optimal functionality, it is crucial to maintain ambient air temperatures within a precise range: no more than +40°C and no less than -5°C. For sustained efficiency, ensure that the average temperature over any 24-hour period does not exceed +35°C.

2. Our product is the epitome of engineering prowess and is perfectly crafted for seamless indoor installation. It thrives in locations where the altitude is below 2000 meters above sea level, guaranteeing unwavering and dependable operation in every scenario.

3. For conditions at their best, the relative humidity of the surrounding air must be kept at or below 50% when the temperature reaches +40°C. However, as temperatures decrease, a higher relative humidity becomes acceptable—up to 90% at +20°C. It is essential to account for potential condensation resulting from fluctuating temperatures.

4. During installation, vigilantly maintain the inclination of the equipment, ensuring it stays within a 5% deviation from the vertical plane. This precision is critical to preserving the switchgear's exceptional operational performance.

5. The installation environment must be free from severe vibrations and impacts. Such a stable setting is vital to protect the electrical components, preventing any risk of corrosion and ensuring long-term reliability.

6. For clients with specific, unique requirements, we warmly invite you to engage in a dialogue with our manufacturer. Together, we can craft a bespoke solution that aligns seamlessly with your individual needs.

Customizable products
Advanced High Quality Switchgear for Optimal Electrical Distribution Safety

About Us

Advanced High Quality Switchgear for Optimal Electrical Distribution Safety
Ordering Instructions

When placing an order, the User shall provide:

1. A detailed schematic of the main circuit distribution system phase layout. This should include the rated working voltage, current, and precise protection device settings. Additionally, provide any further technical parameters necessary to facilitate bespoke manufacturing and achieve the ideal configuration.

2. Clearly specify the incoming and outgoing cable specifications to ensure exact connectivity and enhance operational efficiency.

3. Supply model, specification, and quantity details for all primary electrical components within the differential cabinet, enabling precise customization that meets your specific operational demands.

4. If bus extrusion or ductwork is to be incorporated between switch cabinets or incoming cabinets, provide precise measurements of span and ground height. This is crucial for achieving perfect alignment and ensuring seamless installation.

5. When employing the switch cabinet in unique environmental settings, it is essential to specify these conditions during the ordering process. This ensures proper adaptation and durability of the product in its intended environment.

6. State your preferred surface color for the switch cabinet, along with any other specific requests. This guarantees that the final product not only meets your functional requirements but also aligns with your aesthetic vision.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.