Ggj Smart Low-Voltage Reactive Power Compensation Unit Distribution Cabinet

Product Details
Customization: Available
Certification: ISO9001
Shell Material: Steel Plate
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Low MOQ
The MOQ for the supplier's products is 1
Customization from Designs
The supplier provides design based customization services
ODM Services
The supplier provides ODM services
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (19)
  • Ggj Smart Low-Voltage Reactive Power Compensation Unit Distribution Cabinet
  • Ggj Smart Low-Voltage Reactive Power Compensation Unit Distribution Cabinet
  • Ggj Smart Low-Voltage Reactive Power Compensation Unit Distribution Cabinet
  • Ggj Smart Low-Voltage Reactive Power Compensation Unit Distribution Cabinet
  • Ggj Smart Low-Voltage Reactive Power Compensation Unit Distribution Cabinet
  • Ggj Smart Low-Voltage Reactive Power Compensation Unit Distribution Cabinet
Find Similar Products
  • Overview
  • Product Description
  • Use Environment
  • Product Parameters
  • Customizable products
  • About Us
  • Ordering Instructions
Overview

Basic Info.

Model NO.
NCGGD02
Voltage Level
Low Voltage
Installation
Fixed
Structure
Cabinet
Current
AC
Output Frequency
50Hz
Operating Voltage
380V
Operating Current
5000A
Use Environment
-20ºC-40ºC
Warranty
24 Months
Transport Package
Standard Export Wooden Box with Pallet
Specification
1000mm*600mm*2200mm
Trademark
Newcom
Origin
Fujian, China
HS Code
8504409999
Production Capacity
2000pieces/Month

Product Description

Product Description

GGJ low-voltage reactive power intelligent compensation device uses computer-aided design (CAD), introduces microcomputer control, implements intelligent tracking and compensation for reactive power, its structure is reasonable, advanced technology, widely used in low-voltage power grid, improve power factor, reduce reactive power loss, improve power supply quality, is a new generation of power-saving products; It is specially used for reactive power compensation of 130-600KVA three-phase transformer.

1.It adopts intelligent controller control, complete functions, reliable performance, and automatic compensation mode: the power factor can be increased to more than 0.9;

2.Real-time display of grid power factor, display range: lag (0.00-0.99), ahead (0.00-0.99);

3.It has a variety of comprehensive protection functions such as overvoltage, overharmonic, overcompensation, system fault, phase loss, overload, etc.;

4.Memorize the set parameters, the system will not lose the parameters after the power failure, and after the power grid returns to normal, it will automatically enter the operation state without personnel on duty;

5.According to the load balance of the power grid, the phase compensation or mixed compensation can be adopted;

6.It has strong anti-interference ability, and can resist the amplitude of 2000V interference pulse directly input from the power grid, which is higher than the national professional standard.

Ggj Smart Low-Voltage Reactive Power Compensation Unit Distribution Cabinet
Ggj Smart Low-Voltage Reactive Power Compensation Unit Distribution Cabinet
Use Environment

1.Altitude: ≤ 2000m;

2.Ambient temperature: ≤ -20°C ~ +45°C;

3.Relative humidity: ≤ 90% at 20°C;

4.Installation environment: no harmful gases and vapors, no conductive or explosive dust particles and serious mold.

 
Product Parameters

1.Rated voltage: 0.38-0.66kv;
2.Rated frequency: 50Hz;
3.Rated capacity: 1-600Kvar;
4.Voltage range: (0.85-1.1) times the rated voltage;
5.Maximum operating current: 1.3 times the rated current;
6.Control circuit: 1-16 circuits;
7.Switching time: 1-150S/time, adjustable;
Working mode: automatic, continuous operation.

Customizable products

Ggj Smart Low-Voltage Reactive Power Compensation Unit Distribution Cabinet

About Us

Ggj Smart Low-Voltage Reactive Power Compensation Unit Distribution Cabinet
Ordering Instructions

When placing an order, the User shall provide:

1. Main circuit distribution system diagram phase layout diagram. Rated working voltage, rated working current, protection device walking current and necessary technical parameters.

2. Indicate the specifications of incoming and outgoing cables.

3. The model, specification and quantity of the main electrical components in the differential cabinet.

4.  If the bus extrusion or bus duct is required between the switch cabinets or the incoming cabinets, the specific required data such as span and height from the ground shall be indicated.

5.  When the switch cabinet is used under special environmental conditions, it should be detailed when ordering.

6.  Surface color of the switch cabinet and other specific requirements.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier